EUROPEAN / INTERNATIONAL STANDARDS – AUXILIARY PERFORMANCE & SAFETY | |
---|---|
Colour Fastness to Light | ISO 105-B02, Method 3 — Passes Requirements |
Slip Resistance (Wet) | DIN 51130, Grade R10: >10° and <19° — Surpasses Requirements |
Slip Resistance (Australia/New Zealand) | AS 4586, P4: SRV 45-54 — Surpasses Requirements |
Slip Resistance (UK) | BS 7976-2+A1, PTV 36+ (Low Slip Potential – Dry & Wet) |
Resistance to Staining | EN ISO 26987:2012 — O (Not Affected/Unchanged) |
Density | ISO 23996:2007 Method A — 1589 kg/m³ |
Thickness of Wear Layer | ISO 24340:2006 — Surpasses Requirements |
Impact Sound Insulation | EN ISO 10140-3 / ISO 717-2 — ΔLw = 20 dB |
A-weighted Walking Sound Pressure Level | EN 16205:2013 — Lₐ = 80 dB(A) |
REACH SVHC 191 Compliance | Refer to Standard — Passes Requirements |
EUROPEAN / INTERNATIONAL STANDARDS – CE CERTIFICATION / TESTING | |
CE Certification | EN 14041 — Passes Requirements |
Reaction to Fire (and Smoke Production) | EN 13501-1 / EN ISO 9239-1 — Bfl – S1 Classification Critical Flux: 28.0 kW/m², Flame Spread: 150 mm within 20s, Smoke ≤ 750% |
Flammability (Small Flame Test) | EN ISO 11925-2 — Passes Requirements |
Formaldehyde Emission | EN 717-1 — Class E1, Release ≤ 0.124 mg/m³ |
Content of PCP | EN 12673:1999 — < 5 ppm — Passes Requirements |
Slip Resistance (Dry) | EN 13893 — Class DS, Coefficient ≥ 0.30 |
Static Electrical Propensity | EN 1815 Method A — Antistatic (≤ 2.0 kV) — Passes |
Thermal Resistance (TR) | EN 12664 — 0.051 m²·K/W |
Thermal Conductivity (TC) | EN 12664 — 0.102 W/m·K |
Order now and get it delivered within 24 to 48 hours!
Reviews
There are no reviews yet.